DEYE SUN 12 Inverter

by LOXONE5 (1)1,899 downloads

Content languageEnglish

Description

Basic input registers of a DEYE SUN 12 inverter over modbus.


Modbus extention setup:

Modbus rate: 9600

Stop bits: 1

Parity: None

Timing: Auto


In the example Config File in Additonal Downloads an example application of these templates is shown

Inputs and outputs · 46

NameTypeUnit
PV1 input powerModbus
PV2 input powerModbus
PV3 input powerModbus
PV4 input powerModbus
DC Voltage 1Modbus
DC Voltage 2Modbus
DC Voltage 3Modbus
DC Voltage 4Modbus
Inverter Output Total PowerModbus
Grid Side Total PowerModbus
Battery power flowModbus
Battery temperatureModbus
Battery VoltageModbus
Battery SOCModbus
Load Total PowerModbus
Run StateModbus
Battery Total ChargeModbus
Battery Total DischargeModbus
Grid chargeModbus
Solar sellModbus
TP1 Grid charge enabledModbus
TP2 Grid charge enabledModbus
TP3 Grid charge enabledModbus
TP4 Grid charge enabledModbus
TP5 Grid charge enabledModbus
TP6 Grid charge enabledModbus
TP1 CapacityModbus
TP2 CapacityModbus
TP3 CapacityModbus
TP4 CapacityModbus
TP5 CapacityModbus
TP6 CapacityModbus
Grid chargeModbus
Solar sellModbus
TP1 Grid charge enabledModbus
TP2 Grid charge enabledModbus
TP3 Grid charge enabledModbus
TP4 Grid charge enabledModbus
TP5 Grid charge enabledModbus
TP6 Grid charge enabledModbus
TP1 CapacityModbus
TP2 CapacityModbus
TP3 CapacityModbus
TP4 CapacityModbus
TP5 CapacityModbus
TP6 CapacityModbus

FAQ

No questions have been answered yet.

Ratings and comments

  1. Rated 5 of 5

    Thank you for template saved a lot of time. everything is working out of the box.

Questions and answers

  1. How to plug in SUN 10K?

    Open

    What port are you plugging into on the Deye? Modebus? And what is the pinout? Thank you

    2 replies

    1. in den BMS Port, Ader 1 und 2 oder 7 und 8.

    2. Geht auch im RS485 Port Ader 1 & 2

  2. Modbus Air Extension

    Open

    Hello, thank you very much for the library, I tried to receive the data with the Modbus Air interface, unfortunately I get no data. Is it possible that this is not possible? Which interface does the device have to be connected to exactly, the Modbus or the BMS interface?

    Does the Modbus interface have to be activated? Or is a specific firmware required?

    1 reply

    1. It works now, you had to go to Slave in the WR under Advanced Settings and set the address from 00 to 01, then the Modbus Air received the data immediately.

  3. How to connect ModBus communication with SUN 6K (10K)?

    Open

    I have a LIFEPO4 battery communication with AKUBOX connected to the BMS port, I have an Eastron SDM630 connected to the Meter-485 port. Is it possible to connect a Modbus extension to Modebus ? Or how would you solve it ?

    No replies

  4. CRC Errors Using Loxone's Deye SUN 12K SG04LP3 Library

    Open

    I am using the Loxone-provided library for the Deye SUN 12K SG04LP3 inverter and have encountered intermittent CRC errors when communicating via Modbus RTU. These errors do not appear consistently but occur frequently enough to cause concern.

    Could you please advise on possible causes and solutions for these CRC errors? Are there any recommended settings, firmware updates, or troubleshooting steps I should follow?

    No replies

  5. CRC Errors Using Loxone's Deye SUN 12K SG04LP3 Library

    Open

    I am using the Loxone-provided library for the Deye SUN 12K SG04LP3 inverter and have encountered intermittent CRC errors when communicating via Modbus RTU. These errors do not appear consistently but occur frequently enough to cause concern.

    Could you please advise on possible causes and solutions for these CRC errors? Are there any recommended settings, firmware updates, or troubleshooting steps I should follow?

    No replies

  6. Does it work with Modbus TCP?

    Open

    A Modbus extension is needed, or it also works via Modbus TCP (with a connected DEYE LSE-3 Stick logger)?

    1 reply

    1. It works without a modbus extension via MODBUS TCP. Set the inverter as SLAVE and adress to 01 (not 00) and use port 8899 instead of the standard 502 for MODBUS TCP communication. Thus it works fine for me with the LSE-3 Logger.

  7. Modbus TCP

    Open

    Do you know if it's possible to work also ModBUS TCP with the WIFI logger? or only with the LAN logger? I have a wifi loger, I set slave and 01 address modbus, on 8899 port, but i did not receive data; thank you

    No replies

  8. Compatiblity

    Open

    Hello is it with Deye Hybrid-Wechselrichter SUN-20K-SG05LP3-EU-SM2 20 kW 3 Phasen 48V Compatible and modbus tcp?

    Do i need extra Hardware? Thanks in advice

    No replies