Skip to content
Image of Alnor HRU-P
TemplateVerified by LOXONE

Alnor HRU-P

by Alnor Systemy Wentylacji Sp. z o. o.No rating yet130 downloads

Content languageEnglish

Description

This template allows you to fully control your HRU-P (wired control system) with modbus R/RW registers . 


As part of the system, it is necessary to have the Modbus Extension from Loxone.


__________________________________________________________________________________________________


Combing a heat recovery unit with the loxone system offers the possibility of:


  • Addition of functional construction diagram to the mobile application,
  • Ability to monitor the unit's operation,
  • Control of individual fan speed settings,
  • Monitoring of indoor air quality based on readings from internal and external sensors,
  • Manual control of the damper bypassing the heat exchanger,
  • Possibility to divide the house into separate air distribution zones using a zoning system


__________________________________________________________________________________________________

Depending on the model, there are two types of connections for Modbus Extension to the PCB controlling the devices.


Structure for HRU-SlimAIR-P, HRU-PremAIR-P, HRU-MinistAIR-P:



__________________________________________________________________________________________________


Structure for FlatAIR/ FlatAIR -X/ FlatAIR -Xwall/BoxAir/MaistAIR:



__________________________________________________________________________________________________


Zoning system:

Zoning is a solution designed for residential ventilation systems that divides the supply air system into minimum two controlled zones. Why ventilate rooms when no one is there? Airflow is controlled by dampers with actuators, which are regulated based on demand signals sent by CO2 sensors installed in each zone. This system detects the presence of occupants and delivers the right amount of fresh air at the right time and in the right place.


The template includes a dedicated zoning program for Alnor units, which allows you to divide your home into several ventilation zones.



Functional scheme depending on the unit:


HRU-SlimAIR-P



HRU-PremAIR-P



HRU-MinistAIR-P



HRU-FlatAIR-P



HRU-BoxAIR-P

HRU-MaistAIR

__________________________________________________________________________________________________


Functionality shortcuts:



__________________________________________________________________________________________________


Inputs and outputs · 71

NameTypeUnit
Error Status (R)Modbus
Work Mode (RW)Modbus
Exhaust temperature sensor (R)Modbus
Extract temperature sensor (R)Modbus
Inlet temperature sensor (R)Modbus
Supply temperature sensor (R)Modbus
Pre-heater thermostat (R)Modbus
Afterheater thermostat (R)Modbus
Bypass status (R)Modbus
SAP signal (R)Modbus
Pre-heater status (R)Modbus
Afterhater status (R)Modbus
Bypass position (R)Modbus
Time Mode OUT (RW)Modbus
Time Mode PARTY (RW)Modbus
Fireplace Mode (RW)Modbus
Supply fan speed (R)Modbus
Exhaust fan speed (R)Modbus
Supply fan speed - Speed 1 (RW)Modbus
Supply fan speed - Speed 2 (RW)Modbus
Supply fan speed - Speed 3 (RW)Modbus
Exhaust fan speed - Speed 2 (RW)Modbus
Exhaust fan speed - Speed 3 (RW)Modbus
Exhaust fan speed - Speed 1 (RW)Modbus
Flow setpoint supply (R)Modbus
Supply fan flow - Speed 2 (RW)Modbus
Flow setpoint exhaust (R)Modbus
Flow reading supply (R)Modbus
Flow reading exhaust (R)Modbus
Supply fan flow - Speed 1 (RW)Modbus
Supply fan flow - Speed 3 (RW)Modbus
Exhaust fan flow - Speed 1 (RW)Modbus
Exhaust fan flow - Speed 2 (RW)Modbus
Exhaust fan flow - Speed 3 (RW)Modbus
GHE status (R)Modbus
GHE mode (RW)Modbus
GHE winter temperature (RW)Modbus
GHE summer temperature (RW)Modbus
Turn ON/OFF (RW)Modbus
Supply filter days left (R)Modbus
Exhaust filter days left (R)Modbus
Supply air filter - depletion (R)Modbus
Exhaust air filter - depletion (R)Modbus
Reset filter counting (RW)Modbus
Bypass control (RW)Modbus
Airing time mode (RW)Modbus
Humidity indoor (R)Modbus
CO2 indoor (R)Modbus
Work Mode (RW)Modbus
Time Mode OUT (RW)Modbus
Time Mode PARTY (RW)Modbus
Fireplace Mode (RW)Modbus
Supply fan speed - Speed 1 (RW)Modbus
Supply fan speed - Speed 2 (RW)Modbus
Supply fan speed - Speed 3 (RW)Modbus
Exhaust fan speed - Speed 1 (RW)Modbus
Exhaust fan speed - Speed 3 (RW)Modbus
Exhaust fan speed - Speed 2 (RW)Modbus
Supply fan flow - Speed 1 (RW)Modbus
Supply fan flow - Speed 2 (RW)Modbus
Supply fan flow - Speed 3 (RW)Modbus
Exhaust fan flow - Speed 1 (RW)Modbus
Exhaust fan flow - Speed 2 (RW)Modbus
Exhaust fan flow - Speed 3 (RW)Modbus
GHE mode (RW)Modbus
GHE winter temperature (RW)Modbus
GHE summer temperature (RW)Modbus
Turn ON/OFF (RW)Modbus
Reset filter counting (RW)Modbus
Bypass control (RW)Modbus
Airing time mode (RW)Modbus

FAQ

No questions have been answered yet.

Ratings and comments

No ratings or comments yet.

Questions and answers

No questions have been asked yet.

Report this entry

Report abuse